EXOPTION, Ldtype
,
Option
, VALUE
Specifies the EXPROFILE options for the Mechanical APDL to
ANSYS CFX profile file transfer.
Ldtype
Load type:
SURF | — | Surface load |
VOLU | — | Volume load |
Option
Surface options:
Precision | — | Number of significant digits for the fractional part of real data |
Connectivity | — | Key to include face connectivity in the exported profile file |
Volume options:
Precision | — | Number of significant digits after the decimal for real data |
VALUE
Specify the value for either Precision or Connectivity.
For Precision, specify the number of significant digits. Can be any value between 1 to 20, default 8. When 0 or an invalid value is specified, the program will use the default value of 8 and issue a warning message.
For Connectivity, specify the key to include the element face connectivity data for surface loads (does not support volume loads):
OFF | — | Do not include the connectivity data in the exported file (default) |
ON | — | Include the connectivity data in the exported file |