MAP, --
, kDIM
, --
, kOUT
, LIMIT
Maps pressures from source points to target surface elements.
--
Unused field.
kDIM
Interpolation key:
0 or 2 | — | Interpolation is done on a surface (default). |
3 | — | Interpolation is done within a volume. This option is useful if the supplied source data is volumetric field data rather than surface data. |
--
Unused field.
kOUT
Key to control how pressure is applied when a target node is outside of the source region:
0 | — | Use the pressure(s) of the nearest source point for target nodes outside of the region (default). |
1 | — | Set pressures outside of the region to zero. |
LIMIT
Number of nearby points considered for interpolation.
The minimum is 5; the default is 20. Lower values reduce processing
time. However, some distorted or irregular meshes will require a higher LIMIT
value to find the points encompassing the target
node in order to define the region for interpolation.