PRRFOR, Lab
Prints the constrained node reaction solution. Used with
the FORCE command.
Lab
Nodal reaction load type. If blank, use the first ten of all available labels. Valid labels are:
Structural force labels: FX, FY or FZ (forces); F (FX, FY and FZ); MX, MY or MZ (moments); M (MX, MY and MZ). |
Thermal force labels: HEAT, HBOT, HE2, HE3, . . ., HTOP (heat flow). |
Fluid force labels: FLOW (fluid flow); VFX, VFY and VFZ (fluid forces); VF (VFX, VFY and VFZ). |
Electric force labels: AMPS (current flow); CHRG (charge); CURT (current); VLTG (voltage drop). |
Magnetic force labels: FLUX (magnetic flux); CSGX, CSGY, CSGZ (magnetic current segments); CSG (CSGX, CSGY and CSGZ); CURT (current), VLTG (voltage drop). |
Diffusion labels: RATE (diffusion flow rate). |
PRRFOR has the same functionality as the PRRSOL command; use PRRFOR instead of PRRSOL when a FORCE command has been issued.
In a non-spectrum analysis, if either contact or pretension elements exist in the model, PRRFOR uses the PRRSOL command internally and the FORCE setting is ignored.
Because modal displacements cannot be used to calculate contact element nodal forces, those forces are not included in the spectrum and PSD analyses reaction solution. As a consequence, the PRRFOR command is not supported when constraints on contact element pilot nodes are present.
When using PRRFOR in a spectrum analysis after the combination file has been input (/INPUT,,MCOM), or in a PSD analysis when postprocessing 1-sigma results (loadstep 3, 4, or 5), the following message will display in the printout header:
(Spectrum analysis summation is used)
This message means that the summation of the element nodal forces is performed prior to the combination of those forces. In this case, RSYS does not apply, and the reaction forces are in the nodal coordinate systems. Unlike PRRSOL, which retrieves the forces from the database, the PRRFOR command calculates the forces in the postprocessor.
The spectrum analysis summation is available when the element
results are written to the mode file, Jobname.MODE (MSUPkey
= Yes on MXPAND).
The spectrum analysis summation is not available after reading a load case (LCWRITE, LCZERO, LCASE).