TRNOPT, Method
,
MAXMODE
, --
,
MINMODE
, MCout
,
TINTOPT
, VAout
,
DMPSFreq
Specifies transient analysis options.
Method
Solution method for the transient analysis:
FULL | — | Full method (default). |
MSUP | — | Mode-superposition method. |
MAXMODE
Largest mode number to be used to calculate the response
(for Method
= MSUP). Defaults to the highest
mode calculated in the preceding modal analysis.
--
Unused field.
MINMODE
Smallest mode number to be used (for Method
= MSUP). Defaults to 1.
MCout
Modal coordinates output key (valid only for the mode-superposition method):
NO | — | No output of modal coordinates (default). |
YES | — | Output modal coordinates to the text file Jobname.MCF. |
TINTOPT
Time integration method for the transient analysis:
NMK or 0 | — | Newmark algorithm (default). |
HHT or 1 | — | HHT algorithm (valid only for the full transient method). |
VAout
Velocities and accelerations output key (valid only for mode-superposition transient analysis):
NO | — | No output of velocities and accelerations (default). |
YES | — | Write velocities and accelerations. |
DMPSFreq
Average excitation frequency (Hz) for the calculation of equivalent viscous damping from structural damping input (DMPSTR and MP,DMPR). See Damping for more details. Defaults to zero and structural damping is ignored.
Specifies transient analysis (ANTYPE,TRANS) options. If used in SOLUTION, this command is valid only within the first load step. Use the TINTP command to set transient integration parameters.
To include residual vectors in your mode-superposition transient analysis
(Method
= MSUP), specify RESVEC,ON.
Method
= MSUP is not available for ocean loading.
This command is also valid in PREP7.
Additional product restrictions for the TRNOPT command are shown in the table below.
Command Option Method | Available Products |
FULL (DOF = Structural) | – | – | Enterprise | Ent PP | Ent Solver | – |
FULL (DOF = Temp) | Pro | Premium | Enterprise | Ent PP | Ent Solver | – |
MSUP | – | Premium | Enterprise | Ent PP | Ent Solver | – |