BFL, Line
, Lab
, VAL1
, VAL2
, VAL3
, VAL4
Defines a body force load on a line.
Line
Line to which body load applies. If ALL, apply to
all selected lines [LSEL]. A component name may
also be substituted for Line
.
Lab
Valid body load label. Load labels are listed under "Body loads" in the input table for each element type in the Element Reference.
Discipline | Body Load Label | Label Description |
---|---|---|
Structural Thermal | TEMP | temperature |
FLUE | fluence | |
HGEN | heat generation rate | |
Magnetic | TEMP | temperature |
Electric | TEMP | temperature |
CHRGD | charge density | |
Acoustic | JS | mass source or mass source rate |
TEMP | temperature |
VAL1
, VAL2
, VAL3
Value associated with the Lab
item or a table name for specifying tabular boundary conditions.
Use only VAL1
for TEMP, FLUE, HGEN, and
CHRGD. For acoustics, if Lab
= JS, use VAL1
for mass source in a harmonic analysis or mass
source rate in a transient analysis, and ignoreVAL2
and VAL3
. When specifying a table name,
you must enclose the table name in percent signs (%), e.g., BFL,Line
,Lab
,%tabname
%. Use the *DIM command to define a table.
VAL4
If Lab
= JS, VAL4
is the phase angle in degrees.
Defines a body force load (such as temperature in a structural analysis, heat generation rate in a thermal analysis, etc.) on a line. Body loads may be transferred from lines to line elements (or to nodes if line elements do not exist) with the BFTRAN or SBCTRAN commands.
You can specify a table name only when using temperature (TEMP) and heat generation rate (HGEN) body load labels.
Body loads specified by the BFL command can conflict with other specified body loads. See Resolution of Conflicting Body Load Specifications in the Basic Analysis Guide for details.
Graphical picking is available only via the listed menu paths.
This command is also valid in PREP7.