EDCADAPT, FREQ
, TOL
, OPT
, MAXLVL
, BTIME
, DTIME
, LCID
, ADPSIZE
, ADPASS
, IREFLG
, ADPENE
, ADPTH
, MAXEL
Specifies adaptive meshing controls for an explicit dynamic analysis.
FREQ
Time interval between adaptive mesh refinements (default =
0.0). Use FREQ
= STAT to list the current adaptive
meshing control settings.
TOL
Adaptive angle tolerance (in degrees) for which adaptive meshing will occur (default = 1e31). If the relative angle change between elements exceeds the specified tolerance value, the elements will be refined.
OPT
Adaptivity option:
1 | — | Angle change (in degrees) of elements is based on original mesh configuration (default). |
2 | — | Angle change (in degrees) of elements is incrementally based on previously refined mesh. |
MAXLVL
Maximum number of mesh refinement levels (default = 3). This parameter controls the number of times an element can be remeshed. Values of 1, 2, 3, 4, etc. allow a maximum of 1, 4, 16, 64, etc. elements, respectively, to be created for each original element.
BTIME
Birth time to begin adaptive meshing (default = 0.0).
DTIME
Death time to end adaptive meshing (default = 1e31).
LCID
Data curve number (previously defined on the EDCURVE command)
identifying the interval of remeshing (no default). The abscissa of the data
curve is time, and the ordinate is the varied adaptive time interval. If LCID
is nonzero, the adaptive frequency (FREQ
) is replaced
by this load curve. Note that a nonzero FREQ
value
is still required to initiate the first adaptive loop.
ADPSIZE
Minimum element size to be adapted based on element edge length (default = 0.0).
ADPASS
One or two pass adaptivity option.
0 | — | Two pass adaptivity (default). |
1 | — | One pass adaptivity. |
IREFLG
Uniform refinement level flag (no default). Values of 1, 2, 3, etc. allow 4, 16, 64, etc. elements, respectively, to be created uniformly for each original element.
ADPENE
Adaptive mesh flag for starting adaptivity when approaching
(positive ADPENE
value) or penetrating (negative ADPENE
value)
the tooling surface (default = 0.0).
ADPTH
Absolute shell thickness level below which adaptivity should
begin. This option works only if the adaptive angle tolerance (TOL
)
is nonzero. If thickness based adaptive remeshing is desired without angle
change, set TOL
to a large angle. The default is ADPTH
=
0.0, which means this option is not used.
MAXEL
Maximum number of elements at which adaptivity will be terminated (no default). Adaptivity is stopped if this number of elements is exceeded.
The EDCADAPT command globally sets the control options
for all part IDs that are to be adaptively meshed (see the EDADAPT command).
Because FREQ
defaults to zero, you must input a
nonzero value in this field in order to activate adaptive meshing. You must
also specify a reasonable value for TOL
since the
default adaptive angle tolerance (1e31) will not allow adaptive meshing to
occur.
The EDCADAPT command is not supported in an explicit dynamic full restart analysis (EDSTART,3).
This command is also valid in PREP7.
Distributed ANSYS Restriction This command is not supported in Distributed ANSYS.