FDELE

FDELE, NODE, Lab, NEND, NINC, Lkey
Deletes force loads on nodes.

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | DYNA

NODE

Node for which force is to be deleted. If ALL, NEND and NINC are ignored and forces are deleted on all selected nodes [NSEL]. If NODE = P, graphical picking is enabled and all remaining command fields are ignored (valid only in the GUI). A component name may also be substituted for NODE.

Lab

Valid force label. If ALL, use all appropriate labels. Structural labels: FX, FY, or FZ (forces); MX, MY, or MZ (moments). Thermal labels: HEAT, HBOT, HE2, HE3, . . ., HTOP (heat flow). Fluid labels: FLOW (fluid flow). Electric labels: AMPS (current flow), CHRG (electric charge). Magnetic labels: FLUX (magnetic flux); CSGX, CSGY, or CSGZ (magnetic current segments). Diffusion labels: RATE (diffusion flow rate).

NEND, NINC

Delete forces from NODE to NEND (defaults to NODE) in steps of NINC (defaults to 1).

Lkey

Lock key:

(blank)

 — 

The DOF is not locked (default).

FIXED

 — 

Displacement on the specified degrees of freedom (Lab) is locked. The program prescribes the degree of freedom to the “current” relative displacement value in addition to deleting the force. If a displacement constraint (for example, D command) is applied in conjunction with this option, the actual applied displacement will be ramped during the next load step. The displacement is ramped from the current value to the newly defined value. This option is only valid for the following labels: FX, FY, FZ, MX, MY, MZ. This option is intended primarily for use in the ANSYS Workbench interface to apply an increment length adjustment (bolt pretension loading).

Notes

The node and the degree of freedom label corresponding to the force must be selected [NSEL, DOFSEL].

This command is also valid in PREP7.

Menu Paths

Main Menu>Preprocessor>Loads>Define Loads>Delete>All Load Data>All Forces>On All Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Electric>Excitation>AppCharge>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Electric>Excitation>AppCurrent>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Electric>Excitation>ImprCurr>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Fluid/ANSYS>Flow>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Magnetic>Other>AppCurrSeg>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Magnetic>Other>AppMagFlux>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Structural>Force/Moment>On Node Components
Main Menu>Preprocessor>Loads>Define Loads>Delete>Structural>Force/Moment>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Structural>Spectrum>MultiPtNod>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Structural>Spectrum>NodePSD>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Structural>Spectrum>SinglPtFor>On Nodes
Main Menu>Preprocessor>Loads>Define Loads>Delete>Thermal>Heat Flow>On Nodes
Main Menu>Solution>Define Loads>Delete>All Load Data>All Forces>On All Nodes
Main Menu>Solution>Define Loads>Delete>Electric>Excitation>AppCharge>On Nodes
Main Menu>Solution>Define Loads>Delete>Electric>Excitation>AppCurrent>On Nodes
Main Menu>Solution>Define Loads>Delete>Electric>Excitation>ImprCurr>On Nodes
Main Menu>Solution>Define Loads>Delete>Fluid/ANSYS>Flow>On Nodes
Main Menu>Solution>Define Loads>Delete>Magnetic>Other>AppCurrSeg>On Nodes
Main Menu>Solution>Define Loads>Delete>Magnetic>Other>AppMagFlux>On Nodes
Main Menu>Solution>Define Loads>Delete>Structural>Force/Moment>On Node Components
Main Menu>Solution>Define Loads>Delete>Structural>Force/Moment>On Nodes
Main Menu>Solution>Define Loads>Delete>Structural>Spectrum>MultiPtNod>On Nodes
Main Menu>Solution>Define Loads>Delete>Structural>Spectrum>NodePSD>On Nodes
Main Menu>Solution>Define Loads>Delete>Structural>Spectrum>SinglPtFor>On Nodes
Main Menu>Solution>Define Loads>Delete>Thermal>Heat Flow>On Nodes

Release 18.2 - © ANSYS, Inc. All rights reserved.