FREQ

FREQ, FREQ1, FREQ2, FREQ3, FREQ4, FREQ5, FREQ6, FREQ7, FREQ8, FREQ9
Defines the frequency points for the SV vs. FREQ tables.

Compatible Products: – | – | Premium | Enterprise | Ent PP | Ent Solver | –

FREQ1, FREQ2, FREQ3, . . . , FREQ9

Frequency points for SV vs. FREQ tables. Values must be in ascending order. FREQ1 should be greater than zero. Units are cycles/time.

Command Default

No frequency table.

Notes

Repeat the FREQ command for additional frequency points (100 maximum). Values are added after the last nonzero frequency. If all fields (FREQ1 -- FREQ9) are blank, erase SV vs. FREQ tables.

Frequencies must be in ascending order.

Spectral values are input with the SV command and interpreted according to the SVTYP command. Applies only to the SPRS (single-point) option of the SPOPT command. See the SPFREQ command for frequency input in MPRS (multi-point) analysis.

Use the STAT command to list current frequency points.

This command is also valid in PREP7.

Menu Paths

Main Menu>Preprocessor>Loads>Load Step Opts>Spectrum>SinglePt>Erase Table
Main Menu>Preprocessor>Loads>Load Step Opts>Spectrum>SinglePt>Freq Table
Main Menu>Solution>Load Step Opts>Spectrum>SinglePt>Erase Table
Main Menu>Solution>Load Step Opts>Spectrum>SinglePt>Freq Table