KSEL

KSEL, Type, Item, Comp, VMIN, VMAX, VINC, KABS
Selects a subset of keypoints or hard points.

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | DYNA

Type

Label identifying the type of select:

S

 — 

Select a new set (default).

R

 — 

Reselect a set from the current set.

A

 — 

Additionally select a set and extend the current set.

U

 — 

Unselect a set from the current set.

ALL

 — 

Restore the full set.

NONE

 — 

Unselect the full set.

INVE

 — 

Invert the current set (selected becomes unselected and vice versa).

STAT

 — 

Display the current select status.

The following fields are used only with Type = S, R, A, or U:

Item

Label identifying data. Valid item labels are shown in the table below. Some items also require a component label. If Item = PICK (or simply “P”), graphical picking is enabled and all remaining command fields are ignored (valid only in the GUI). Defaults to KP.

Comp

Component of the item (if required). Valid component labels are shown in the table below.

VMIN

Minimum value of item range. Ranges are keypoint numbers, coordinate values, attribute numbers, etc., as appropriate for the item. A component name (as specified on the CM command) may also be substituted for VMIN (VMAX and VINC are ignored). If Item = MAT, TYPE, REAL, or ESYS and if VMIN is positive, the absolute value of Item is compared against the range for selection; if VMIN is negative, the signed value of Item is compared. See the KLIST command for a discussion of signed attributes.

VMAX

Maximum value of item range. VMAX defaults to VMIN.

VINC

Value increment within range. Used only with integer ranges (such as for keypoint numbers). Defaults to 1. VINC cannot be negative.

KABS

Absolute value key:

0

 — 

Check sign of value during selection.

1

 — 

Use absolute value during selection (sign ignored).

Command Default

All keypoints are selected.

Notes

Selects a subset of keypoints or hard points. For example, to select a new set of keypoints based on keypoint numbers 1 through 7, use KSEL,S,KP,,1,7. The selected subset is used when the ALL label is entered (or implied) on other commands, such as KLIST,ALL. Only data identified by keypoint number are selected. Data are flagged as selected and unselected; no data are actually deleted from the database.

This command is valid in any processor.

For selections based on non-integer numbers (coordinates, results, etc.), items that are within the range VMIN -Toler and VMAX + Toler are selected. The default tolerance Toler is based on the relative values of VMIN and VMAX as follows:

  • If VMIN = VMAX, Toler = 0.005 x VMIN.

  • If VMIN = VMAX = 0.0, Toler = 1.0E-6.

  • If VMAXVMIN, Toler = 1.0E-8 x (VMAX - VMIN).

Use the SELTOL command to override this default and specify Toler explicitly.

Table 193:  KSEL - Valid Item and Component Labels

Valid Item and Component Labels KSEL, Type, Item, Comp, VMIN, VMAX, VINC, KABS
ItemCompDescription
KP Keypoint number.
EXT Keypoint numbers on exterior of selected lines (ignore remaining fields).
HPT Hard point number.
LOCX,Y,ZX, Y, or Z location in the active coordinate system.
MAT Material number associated with the keypoint.
TYPE Element type number associated with the keypoint.
REAL Real constant set number associated with the keypoint.
ESYS Element coordinate system associated with the keypoint.

Menu Paths

Utility Menu>Select>Entities

Release 18.2 - © ANSYS, Inc. All rights reserved.