LSSOLVE, LSMIN
, LSMAX
, LSINC
Reads and solves multiple load steps.
LSMIN
, LSMAX
, LSINC
Range of load step files to be read and solved, from LSMIN
to LSMAX
in steps
of LSINC
. LSMAX
defaults to LSMIN
, and LSINC
defaults to 1. If LSMIN
is blank, a brief
command description is displayed. The load step files are assumed
to be named Jobname.Sn
, where n
is a number
assigned by the LSWRITE command (01--09,10,11,
etc.). On systems with a 3-character limit on the extension, the "S" is dropped for numbers > 99.
LSSOLVE invokes an ANSYS macro to read and solve multiple load steps. The macro loops through a series of load step files written by the LSWRITE command. The macro file called by LSSOLVE is called LSSOLVE.MAC.
LSSOLVE cannot be used with the birth-death option.
LSSOLVE is not supported for cyclic symmetry analyses.
LSSOLVE does not support restarts.