PLCPLX

PLCPLX, KEY
Specifies the part of a complex variable to display.

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | DYNA

KEY

Complex variable part:

0

 — 

Amplitude.

1

 — 

Phase angle.

2

 — 

Real part.

3

 — 

Imaginary part.

Notes

Used only with harmonic analyses (ANTYPE,HARMIC).

All results data are stored in the form of real and imaginary components and converted to amplitude and/or phase angle as specified via the PLCPLX command. The conversion is not valid for derived results (such as principal stress/strain, equivalent stress/strain and USUM).

Menu Paths

Main Menu>TimeHist Postpro>Settings>Graph

Release 18.2 - © ANSYS, Inc. All rights reserved.