SENERGY

SENERGY, OPT, ANTYPE
Determines the stored magnetic energy or co-energy.

Compatible Products: – | – | – | Enterprise | Ent PP | Ent Solver | –

OPT

Item to be calculated:

0

 — 

Stored magnetic energy.

1

 — 

Stored magnetic co-energy.

ANTYPE

Analysis type:

0

 — 

Static or transient.

1

 — 

Harmonic.

Notes

SENERGY invokes an ANSYS macro which calculates the stored magnetic energy or co-energy for all selected elements. (For a harmonic analysis, the macro calculates a time-averaged (rms) stored energy.) A summary table listing the energy by material number is produced. The energy density is also calculated and stored on a per-element basis in the element table [ETABLE] with the label MG_ENG (energy density) or MG_COENG (co-energy density). The macro erases all other items in the element table [ETABLE] and only retains the energy density or co-energy density. Use the PLETAB and PRETAB commands to plot and list the energy density. The macro is valid for static and low-frequency magnetic field formulations. The macro will not calculate stored energy and co-energy for the following cases:

  • Orthotropic nonlinear permanent magnets.

  • Orthotropic nonlinear permeable materials.

  • Temperature dependent materials.

SENERGY is restricted to MKSA units.

Distributed ANSYS Restriction This command is not supported in Distributed ANSYS.

Menu Paths

Main Menu>General Postproc>Elec&Mag Calc>Element Based>Co-Energy
Main Menu>General Postproc>Elec&Mag Calc>Element Based>Energy

Release 18.2 - © ANSYS, Inc. All rights reserved.