SPLOT

SPLOT, NA1, NA2, NINC, MESH
Displays the selected areas and a faceted view of their underlying surfaces

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | DYNA

NA1

Starting area for display of areas and underlying surfaces. If NA1 = ALL (default), NA2 and NINC are ignored and all selected areas are displayed (ASEL command).

NA2

Last area to be displayed.

NINC

Numeric value setting steps between NA1 and NA2 for display. Default value is (1).

MESH

Specifies a rectangular mesh density used to display the underlying surface (default 4, i.e. 4 x 4).

Notes

This command is valid in any processor. The plot output displays the external and internal trim curves and underlying surface. You cannot obtain a faceted view of your surface areas when you are using the /EXPAND command to create larger graphics displays.

Use APLOT for trimmed surface display.

Menu Paths

This command cannot be accessed from a menu.

Release 18.2 - © ANSYS, Inc. All rights reserved.