/TRLCY, Lab
, TLEVEL
, N1
, N2
, NINC
Specifies the level of translucency.
Lab
Apply translucency level to the items specified by the following labels:
ELEM | — | Elements. Use |
AREA | — | Solid model areas. Use |
VOLU | — | Solid model volumes. Use |
ISURF | — | Isosurfaces (surfaces of constant stress, etc., value). Translucency varies with result value, to a maximum of the specified translucency level. |
CM | — | Component group. Use |
CURVE | — | Filled areas under curves of line graphs.
Use |
ZCAP | — | If /TYPE, |
ON, OFF | — | Sets the specified translucency display on or off. All other fields are ignored. |
TLEVEL
Translucency level: 0.0 (opaque) to 1.0 (transparent).
N1
, N2
, NINC
Used only with labels as noted above. Apply translucency
level to Lab
items numbered N1
to N2
(defaults
to N1
) in steps of NINC
(defaults
to 1). If N1
is blank or ALL, apply specified
translucency level to entire selected range. If Lab
is
CM, use component name for N1
and ignore N2
and NINC
.
A value of N1
= P allows you to graphically pick
elements, areas, and volumes. You can then assign translucency levels to the
entities via the picker. The Lab
and TLEVEL
fields
are ignored when translucency is applied by picking.
Specifies the level of translucency for various items. Issue /TRLCY,DEFA to reset the default (0) translucency levels. This command is valid only on selected 2-D and 3-D graphics devices; see in the Basic Analysis Guide for more information on applying translucency.
For 2-D devices, ANSYS displays only the visible faces of the items being displayed. The information behind the facing planes is not displayed. Issuing the /SHRINK command will force the hardware to display information behind the translucent items.
This command is valid in any processor.