TSRES, Array
Defines an array of key times at which the time-stepping strategy
changes.
Array
Identifies an N
x1x1
array parameter containing the key times at which the heat transfer time-stepping
strategy changes (the time step is reset to the initial time step based on DELTIM or NSUBST settings).
The array name must be enclosed by % signs (e.g., %array
%).
See *DIM for more information on array parameters.
Time values in the array parameter must be in ascending order and must
not exceed the time at the end of the load step as defined on the TIME command.
The time increment between time points in the array list must be larger than
the initial time step defined on the DELTIM or NSUBST command.
Time values must also fall between the beginning and ending time values of
the load step. For multiple load step problems, you must either change the
parameter values to fall between the beginning and ending time values of the
load step or reissue the command with a new array parameter. To clear the
array parameter specification, issue TSRES,ERASE. Results
can be output at the requested time points if the array or time values in
the array are also specified in the OUTRES command using FREQ
=%array
%.
Use this command to reset the time-stepping strategy within a load step.
You may need to reset the time-stepping strategy when using tabular time-varying
boundary conditions.
See Steady-State Thermal Analysis of the Thermal Analysis Guide for more information on applying boundary conditions via tabular input. See Transient Thermal Analysis of the Thermal Analysis Guide for more information on defining the key time array.