MFLIST

MFLIST, Option, Value
Lists the settings for an ANSYS Multi-field solver analysis.

Compatible Products: – | – | – | Enterprise | Ent PP | Ent Solver | –

Option

ALL

 — 

Lists all ANSYS Multi-field solver analysis options.

SOLU

 — 

Lists all solution-related ANSYS Multi-field solver options.

FIELD

 — 

Lists all ANSYS Multi-field solver options related to the specified field number.

SINT

 — 

Lists all surface interface information for the specified surface interface number.

VINT

 — 

Lists all volumetric interface information for the specified volumetric interface number.

Value

Use only for Option = FIELD, SINT, or VINT.

Option = FIELD lists all ANSYS Multi-field solver options for the field number Value. Value defaults to 0, which lists information for all fields.

Option = SINT lists all surface interface information for the interface number Value. Value defaults to 0, which lists information for all surface interfaces.

Option = VINT lists all volumetric interface information for interface number Value. Value defaults to 0, which lists information for all volumetric interfaces.

Notes

This command is also valid in PREP7.

See Multi-field Commands in the Coupled-Field Analysis Guide for a list of all ANSYS Multi-field solver commands and their availability for MFS and MFX analyses.

Distributed ANSYS Restriction This command is not supported in Distributed ANSYS.

Product Restrictions

ANSYS Mechanical allows MFX analyses but not MFS analyses. ANSYS Multiphysics allows both MFS and MFX analyses.

Menu Paths

Main Menu>Preprocessor>Multi-field Set Up>MFS-Single Code>Status
Main Menu>Preprocessor>Multi-field Set Up>MFX-ANSYS/CFX>Status
Main Menu>Solution>Multi-field Set Up>MFS-Single Code>Status
Main Menu>Solution>Multi-field Set Up>MFX-ANSYS/CFX>Status

Release 18.2 - © ANSYS, Inc. All rights reserved.