MFRELAX, Lab
, VALUE
, Option
Sets relaxation values for an ANSYS Multi-field solver analysis.
Lab
Valid labels:
Force label: FORC |
Displacement label: DISP |
Temperature label: TEMP |
Heat flux label: HFLU |
Heat generation label: HGEN |
If Lab
= ALL, MFRELAX applies the relaxation value to all variables.
VALUE
Relaxation value. Defaults to 0.75 for all labels.
Option
Valid options are:
RELX | — | Uses relaxation method for load transfer (default). |
LINT | — | Uses a linear interpolation for loaf transfer. |
MFRELAX sets relaxation values for the load
transfer variables at a surface or volume interface. Option
= RELX will usually give you a more stable and
smooth load transfer and is suitable for strongly coupled problems
(such as FSI problems). Option
= LINT is
suitable for weakly coupled problems because it will transfer the
full load in fewer stagger iterations.
See the MFFR and MFITER commands for more information on relaxation in the ANSYS Multi-field solver.
This command is also valid in PREP7.
See Multi-field Commands in the Coupled-Field Analysis Guide for a list of all ANSYS Multi-field solver commands and their availability for MFS and MFX analyses.
Distributed ANSYS Restriction This command is not supported in Distributed ANSYS.