MFRSTART

MFRSTART, TIME
Specifies restart status for an ANSYS Multi-field solver analysis.

Compatible Products: – | – | – | Enterprise | Ent PP | Ent Solver | –

TIME

Restart time

  0 

 — 

New analysis (Default)

-1 

 — 

Restart from the last result set from a previous run.

  n 

 — 

Specify any positive number for the actual time point from which the ANSYS Multi-field solver will restart. ANSYS checks the availability of the result set and database file.

Notes

For MFX analyses, ANSYS always passes an actual time value to CFX (zero for a new analysis or a positive value for a restart run) and CFX verifies the consistency with the initial results file. For more details about ANSYS restart capabilities, please see Restarting an Analysis in the Basic Analysis Guide.

See Multi-field Commands in the Coupled-Field Analysis Guide for a list of all ANSYS Multi-field solver commands and their availability for MFS and MFX analyses.

Distributed ANSYS Restriction This command is not supported in Distributed ANSYS.

Product Restrictions

ANSYS Mechanical allows MFX analyses but not MFS analyses. ANSYS Multiphysics allows both MFS and MFX analyses.

Menu Paths

Main Menu>Preprocessor>Multi-field Set Up>MFS-Single Code>Time Ctrl
Main Menu>Preprocessor>Multi-field Set Up>MFX-ANSYS/CFX>Time Ctrl
Main Menu>Solution>Multi-field Set Up>MFS-Single Code>Time Ctrl
Main Menu>Solution>Multi-field Set Up>MFX-ANSYS/CFX>Time Ctrl