RATE

RATE, Option
Specifies whether the effect of creep strain rate will be used in the solution of a load step.

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | –

Option

Activates implicit creep analysis.

0 or OFF 

 — 

No implicit creep analysis. This option is the default.

1 or ON 

 — 

Perform implicit creep analysis.

Command Default

Issuing this command with no arguments deactivates implicit creep analysis.

Notes

Set Option = 1 (or ON) to perform an implicit creep analysis (TB,CREEP with TBOPT   1). For viscoplasticity/creep analysis, Option specifies whether or not to include the creep calculation in the solution of a load step. If Option = 1 (or ON), ANSYS performs the creep calculation. Set an appropriate time for solving the load step via a TIME,TIME command.

Product Restrictions

This command works only when modeling implicit creep with either von Mises or Hill potentials.

When modeling implicit creep with von Mises potential, you can use the following elements: LINK180, SHELL181, PLANE182, PLANE183, SOLID185, SOLID186, SOLID187, SOLID272, SOLID273, SOLID285, SOLSH190, BEAM188, BEAM189, SHELL208, SHELL209, REINF264, SHELL281, and ELBOW290.

When modeling anisotropic creep (TB,CREEP with TB,HILL), you can also use the following elements: LINK180, SHELL181, PLANE182, PLANE183, SOLID185, SOLID186, SOLID187, BEAM188, BEAM189, SOLSH190, SHELL208, SHELL209, REINF264, REINF265, SOLID272, SOLID273, SHELL281, SOLID285, PIPE288, PIPE289, and ELBOW290.

Menu Paths

Main Menu>Preprocessor>Loads>Analysis Type>Sol'n Controls>Nonlinear
Main Menu>Preprocessor>Loads>Load Step Opts>Nonlinear>Strn Rate Effect
Main Menu>Solution>Analysis Type>Sol'n Controls>Nonlinear
Main Menu>Solution>Load Step Opts>Nonlinear>Strn Rate Effect