RIGRESP

RIGRESP, Option, Method, Val1, Val2
Specifies the rigid response calculation.

Compatible Products: – | Pro | Premium | Enterprise | Ent PP | Ent Solver | –

Option

Flag to activate or deactivate the rigid response calculation:

1 (ON or YES)

 — 

Activate.

2 (OFF or NO)

 — 

Deactivate. This value is the default.

Method

Method used to calculate the rigid response:

GUPTA

 — 

Gupta method.

LINDLEY

 — 

Lindley-Yow method.

Val1

If Method = GUPTA, Val1 represents the frequency F1 in Hertz.

If Method = LINDLEY, Val1 is the Zero Period Acceleration (ZPA). If a scale factor is defined (FACT in the SVTYP command), it is used to scale this value

Val2

If Method = GUPTA, Val2 represents the frequency F2 in Hertz.

Notes

This rigid response calculation is only valid for single point response spectrum analysis (SPOPT, SPRS) and multiple point response spectrum analysis (SPOPT, MPRS) with combination methods (SRSS), complete quadratic (CQC) or Rosenblueth (ROSE)

This command is also valid in PREP7.

Menu Paths

This command cannot be accessed from a menu.

Release 18.2 - © ANSYS, Inc. All rights reserved.