MFOUTPUT, FREQ
Specifies results file output frequency for an ANSYS Multi-field solver analysis.
FREQ
| — | Write solution every |
| — | Writes up to |
| — | Suppresses writing of results for all multifield time steps. |
| — | Writes results for every multifield time step (default). |
| — | Writes results for only the last multifield time step. |
| — | Where For restart runs (see MFRSTART command), either change the parameter values to fall between the beginning and ending time values of the load step, or erase the current settings and reissue the command with a new array parameter. For more information about defining array parameters, see the *DIM command documentation. |
A MFOUTPUT setting overrides any other output frequency setting (OUTRES). To select the solution items, use the OUTRES command.
For the case of Freq = -n and Freq = %array%, the results at the time points which first time reaches or exceeds the targeting ouptupt time points will be written.
This command is also valid in PREP7.
See Multi-field Commands in the Coupled-Field Analysis Guide for a list of all ANSYS Multi-field solver commands and their availability for MFS and MFX analyses.